These cables; are used in telecommunication networks for transmission of either analog or digital signals. Maximum operating transmission speed is 155 Mbit/Sn.
Conductor | Ø 0.51 mm Electrolytic Annealed Copper Wire (AWG 24) |
Insulation | According to EN 50290-2, VDE 0207 standards; Polyethylene |
Color Codes (For Pairs) | 1; Blue/White-Blue, 2;Orange/White-Orange 3; Green/White-Green 4; Brown/White-Brown |
Stranding | Two cores twisted in pair and pairs stranded together. |
Seperator | PES Tape |
Drain Wire | Tinned Copper Wire |
Screen | AL-PES Foil |
Outer Sheath | According to BS and EN 50290-2 standards; PVC, Grey-RAL 7001 |
Reference Standards | IEC 189, IEC 708 |
Flame Test | EN, IEC, BS and DIN 60332-1-2 (VDE 0482-332-1-2) |
Technical Characteristics | |
Impedence | 100 ± 15 Ω |
Mutual Capacitance | 56 nF/km |
Conductor Resistance | 94 Ω/km |
Insulation Resistance | >5000 M.Ωxkm |
Operating Temperature Range | -30°C … +70°C |
Operating Voltage | 250 kV |
Test Voltage | 1200 kV |
Minumun Bending Radius | 7.5xD |
Electrical Characteristics |
Frequency | Return Loss | Attenuations | NEXT (Near End Crosstalk) |
MHz | dB | dB/100 m | dB |
1.0 | 23 | 1.9 | 62 |
4.0 | 23 | 4.0 | 53 |
8.0 | 23 | 5.7 | 48 |
10.0 | 23 | 6.3 | 47 |
16.0 | 23 | 8.0 | 44 |
20.0 | 23 | 9.1 | 42 |
25.0 | 22 | 10.3 | 41 |
31.2 | 21 | 11.5 | 39 |
62.5 | 18 | 16.0 | 35 |
100.0 | 16 | 21.0 | 32 |