2YSLCY

Connection cable for electrical drives with high power and servo applications, EMC-optimised and double shielded. These cables connecting cable between frequency converter and motor. These cables can used in dry, damp and wet interiors. Also they are available for paper, chemical and heavy industry.
ConductorAccording to IEC, BS, EN 60228 and VDE 0295 standards; 
Class 5, Stranded Electrolytic Annealed Copper
InsulationAccording to VDE 0207 standard;Polyethylene
Damar Color CodeAccording to VDE 0293 and TS HD 308 S2 standard
StrandingAll cores stranded in layers
FillerAccording to VDE 0207 standard;
Polyethylene
ScreenTinned Copper Wire Braiding
ProtectionAL-PES Tape
Outer SheathAccording to BS, EN 50290-2 and VDE 0207 standards; 
TM1, PVC
Outer Sheath Color CodeTransparent
Reference StandardVDE 0250
Flame TestEN, IEC, BS and DIN 60332-1-2 (VDE 0482-332-1-2)
Technical Characteristics 
Conductor Resistance 0.50 mm²; 39 Ω/km, 0.75 mm²; 26 Ω/km, 
1.00 mm²; 19.5 Ω/km,
2.50 mm²; 7.98 Ω/km; 4 mm²; 4.95 Ω/km, 
6 mm²; 3.3 Ω/km,
10 mm²; 1.91 Ω/km,
16 mm²; 1.21 Ω/km
Insulation Resistance>200 M.Ωxkm
Operating Voltage600 V / 1000 V 
Test Voltage4000 V
Operating Temperature RangeFixed; -30 °C … +70 °C, Flexible; -5 °C … +70 °C
Minumun Bending RadiusFixed; 8xD, Flexible; 15xD
Nominal Cross-SectionOverall Diameter (Approx.)Net Weight (Approx.)Standard Delivery Length
n x mm²mmkg/kmm
4x1.511.5195100/500/1000
4x2.512.5245100/500/1000
4x414.0325100/500/1000
4x615.5415100/500/1000
4x1018.0630100/500/1000
4x1620.5925100/500/1000
4x2526.51360100/500/1000
4x3530.01800100/500/1000